ISO 9001 Certified · FRP/GRP Grating Manufacturer · Since 2004 · Exporting to 45+ Countries

FRP Metering Pump Stands

Dosing skids · pump bases · drip-proof pads

FRP metering pump stand equipment base
Product Overview

FRP Metering Pump Stands

FRP metering pump stands raise chemical metering pumps, dosing skids and feed systems above floor spillage, contain drips and keep equipment corrosion-free. ZeAllgrate fabricates stands and equipment pads from pultruded FRP with a sealed or grated deck, drip tray, and the load capacity for pump and motor weight plus operating vibration.

  • Raises pumps above floor spillage and washdown
  • Corrosion-proof — built for chemical feed service
  • Anti-slip standing surface around the pump
  • Optional drip tray and integral containment
  • Load-rated for pump, motor and vibration loads
  • Custom height, footprint and pipe-support brackets
Applications

Pump Stands for Chemical Feed & Dosing

Engineered for metering pumps, dosing skids, analyzer shelters and small equipment packages where a corrosion-proof, spill-tolerant base extends service life.

Open-mesh FRP grating cover for trench and drain
Metering Pump & Dosing Stands

Bases for diaphragm and piston metering pumps with drip containment and room for tubing, valves and calibration.

Solid FRP cover panel with sealed gritted surface for tank and trench covers
Equipment & Skid Pads

Pads under analyzer skids, feed tanks and instrument packages — levelled, sealed or grated to spec.

Stands are fabricated to your pump footprint, weight and connection layout. Send pump dimensions for a quote →

Key Specifications

Technical Data

TypeFRP Pump Stand / Equipment Base / Drip Pad
MaterialMolded or Pultruded FRP
DeckGrated or solid FRP, anti-slip option
Load ClassA15 / B125 / C250 / D400 / E600 / F900
Panel SizeCustom to pump footprint and height
FramePultruded FRP legs & beams, SS fasteners
HardwareSS304 / SS316
ColorsGrey / Red / Yellow / Green (custom RAL/Pantone)
SurfaceGrit-top / Plain
LockingPadlock / bolt-down optional
Engineering Drawings

Product Drawings & Details

Dimensioned drawings for specification and fabrication — matching the technical documentation of leading FRP manufacturers.

DW-01 G-Clip Fastening — Section
DWG NO: ZL-XDG-01SCALE 1:10UNITS: mmMAT: FRPFRP gratingSupport beamG-clip≥40 mm3–5 mmSS304/316 or FRP clip; min 2 clips per support beam
DW-02 Edge Trim & Cut Edge Sealing
DWG NO: ZL-XDG-02SCALE 1:10UNITS: mmMAT: FRPGrating panelEdge trimSupportCut edges sealed with polyester resin
DW-03 Stair Tread Fixing
DWG NO: ZL-XDG-03SCALE 1:10UNITS: mmMAT: FRPTread w/ nosepieceTread fixed to stringer with SS fasteners
DW-04 Expansion Joint Detail
DWG NO: ZL-XDG-04SCALE 1:10UNITS: mmMAT: FRP3–5 mmContinuous supportExpansion gap at every fixed support
Standard Configurations

Stand Capacity Reference

Indicative stand capacity by configuration — confirm against certified load data for your pump weight and duty.

Load ClassRated LoadTypical ServiceRecommended Use
Light dosingup to 300 kgSmall metering pumps150 – 300 mm stand height
Medium pump300 – 1500 kgMetering / dosing skids300 – 600 mm stand height
Heavy package1.5 – 5 tFeed tanks, analyzer sheltersCustom engineered
A1515 kNPedestrian onlyFootpaths, inspection covers
B125125 kNSidewalks, light vehiclesSidewalks, car parks
C250250 kNVehicle areas (slow)Trench covers, service roads
D400400 kNHeavy vehicle areasLoading docks, industrial yards
E600600 kNForklift / industrialIndustrial floors, warehouses
F900900 kNExtreme industrialRunways, special heavy service

Values are standard industry configurations. Certified load/span charts and test reports provided with every order.

Material Properties

Physical & Mechanical Properties

Typical values tested in accordance with ASTM methods on production panels. Certified test reports available on request.

PropertyValueTest Method
Tensile Strength70 – 220 MPaASTM D638
Flexural Strength110 – 240 MPaASTM D790
Compressive Strength170 – 240 MPaASTM D695
Flexural Modulus8 – 13 GPaASTM D790
Density1.7 – 1.9 g/cm³ASTM D792
Water Absorption (24h)< 0.5%ASTM D570
Flame Spread≤ 25 (Class A)ASTM E84
Product Gallery

In Production & In the Field

Real photographs from our manufacturing facility and installed projects.

Standards & Compliance

Engineered to International Standards

A

ASTM E84

Surface burning characteristics for fire-retardant grades — Class A/Class B options.

I

ISO 14122

Permanent means of access to machinery — platform, walkway and stair requirements.

S

AS 1657

Fixed platforms, walkways, stairways and ladders — design, construction and testing.

O

OSHA 1910

Walking-working surfaces and fall protection compliance for industrial installations.

Material certificates, load test reports and compliance documentation shipped with every order. Certified: ISO 9001:2015 · DNV & ABS Marine · SGS & Intertek. View certifications →

Surfaces & Colors

Options for Every Environment

SurfaceBest ForAnti-Slip
Concave / ConvexGeneral industrial walkways, platformsStandard molded profile
Grit-Top (Silica)Wet, oily and chemical process areasHigh — embedded silica grit
Micro-MeshPublic access, ADA-compliant small openingsHigh — small mesh profile
MeniscusLight pedestrian traffic, aestheticsModerate — meniscus surface

Standard colors: Green (RAL 6010), Gray (RAL 7047), Yellow (RAL 1003), Red, Blue, Black — custom Pantone/RAL matching available.

Chemical Resistance

Chemical Resistance Reference

Indicative chemical resistance by resin system — the basis of every material selection. Always confirm the final recommendation against our certified chemical resistance guide for your specific media, concentration and temperature.

Chemical MediumISO PolyesterVinyl EsterPhenolicService Notes
Sulfuric AcidGoodExcellentFairUp to 50%, 50 °C
Hydrochloric AcidGoodExcellentPoorUp to 37%, 50 °C
Sodium Hydroxide (Caustic)GoodGoodFairUp to 25%, 50 °C
Sodium Hypochlorite (Bleach)FairExcellentPoorUp to 15%, 40 °C
Hydrogen PeroxideFairGoodFairUp to 30%, 40 °C
Organic SolventsFairGoodPoorModerate temperature
Seawater / Salt SprayExcellentExcellentExcellentContinuous marine service
Petroleum / HydrocarbonsGoodExcellentFairModerate temperature
Acetic AcidGoodExcellentFairUp to 25%, 50 °C
Phosphoric AcidGoodExcellentFairUp to 85%, 60 °C

Ratings: Excellent — long-term service; Good — suitable with normal inspection; Fair — limited service, verify application. Full Chemical Resistance Guide →

Resin Systems

Ten Resin Systems for Every Chemical Environment

Corrosion resistance starts with the resin. ZeAllgrate manufactures in ten engineered resin systems, matching the industry’s proven material selection methodology.

Resin SystemKey PropertyMax Service TempTypical Use
Isophthalic Polyester (ISO)General corrosion resistance60 – 70 °CWater/wastewater, industrial floors
ISO Chemical GradeEnhanced chemical resistance70 – 80 °CChemical plant walkways
Vinyl Ester (VE)Superior acid/alkali/solvent resistance80 – 90 °CChemical, bleaching, pulp
VE Chemical GradeMaximum corrosion performance90 – 100 °CHarshest chemical exposure
PhenolicLow smoke, low flame spread120 – 150 °COffshore, fire-critical
Fire Retardant (FR)ASTM E84 Class A, flame spread ≤ 2560 – 70 °CCode-required flame ratings
UV-StabilizedOutdoor UV resistance60 – 70 °CSolar-exposed installations
Heat ResistantHigh-temperature service100 – 120 °CProcess heat areas
Conductive (Carbon)Static-dissipative60 – 70 °CElectrical / explosion areas
Food Grade (FDA)FDA-compliant contact surfaces60 – 70 °CFood & beverage processing

Our engineers prepare a written resin recommendation with every quotation — matched to your media, concentration and service temperature.

Installation

Installation Notes

✂

Cutting

Carbide-tipped or abrasive cutters; support both sides of the cut; wear dust protection. Wet cutting recommended.

🔩

Fastening

Fasten every panel at every support intersection. SS304/316 G-clips in corrosive service; expansion bolts for concrete.

↔

Orientation

Pultruded bearing bars run across the span — never parallel. Leave thermal gaps at fixed supports.

Installation ParameterRecommended PracticeStandard Reference
Support SpacingMaximum span per certified load chart — never exceed recommended clear spanLoad chart per configuration
BearingMinimum 40 mm bearing on each supportZeAllgrate practice / ISO 14122-3
Fastener SpacingMinimum 2 hold-down clips per support beam, spaced ≤ 1219 mm (4 ft) on centre; minimum 4 clips per panelPer ZeAllgrate engineering practice
Thermal ExpansionAllow 3 – 5 mm expansion gap at fixed supports; molded coefficient ≈ 15–25×10⁻⁶ /°C (direction dependent)Manufacturer data
Cut HolesSeal cut edges in chemical service with resin; radius corners to avoid stress pointsDesign guide
Fall ProtectionHandrail height ≥ 1100 mm (ISO 14122-3) / 42 in (OSHA 1910.23); kickplate where requiredOSHA 1910 / ISO 14122

Full Installation Guide →

Resin Systems

Choose the Right Resin for Your Environment

Corrosion resistance starts with the resin system. ZeAllgrate offers 3+ engineered resin systems for every chemical environment.

Isophthalic PolyesterGeneral-purpose corrosion resistance; excellent value for industrial and water/wastewater applications
Vinyl EsterSuperior chemical resistance to acids, alkalis and solvents — for chemical plants and bleaching environments
PhenolicLow smoke, low flame spread and high-temperature performance — for fire-critical and offshore applications
Fire-Retardant (FR)Enhanced flame-retardant grades meeting surface-burning requirements (ASTM E84)
UV-StabilizedUV-inhibited formulations for outdoor and solar-exposed installations

Contact our engineers for a chemical-resistance recommendation matched to your specific media, concentration and temperature.

Selection Process

How to Specify in Four Steps

1

Define Environment

Identify chemicals, temperature, UV exposure and load requirements.

2

Choose Grating Type

Molded for bi-directional strength; pultruded for long spans and heavy loads.

3

Check Load / Span

Verify the support span against certified load charts for your configuration.

4

Specify Surface & Clips

Grit-top for wet areas; SS304/316 clips for secure fastening.

Full Design Guide →

Technical Documents

Datasheets & Downloads

FRP Metering Pump Stands - Technical Data Sheet
PDF · Technical Document
PreviewDownload
ZeAllgrate Product Catalog
PDF · Technical Document
PreviewDownload
FRP Grating Design Guide
PDF · Technical Document
PreviewDownload
FAQ

Frequently Asked Questions

What is the lead time?

Standard panels: 7-15 days production; custom fabrication 15-20 days, plus shipping time. Urgent orders can be prioritized.

Can I get a free sample?

Yes - free small samples are available for evaluation. Contact [email protected] with your application details.

What certificates do you provide?

Material certificates and load test reports are supplied with every shipment. Our facility is ISO 9001:2015 certified; marine grades carry DNV & ABS approvals, and third-party SGS & Intertek inspection and testing is available on request.

Related Technical Articles

Go Deeper with the ZeAllgrate Knowledge Base

📚

Grating Cover Selection

Read article →

Choosing covers by load class, traffic and environment.

📚

Trench Cover Load Ratings

Read article →

Load-rated trench, basin and screening covers.

📚

Load & Span Charts

Read article →

Reading certified load/span tables for cover panels.

📚

Chemical Resistance & Resin Selection

Read article →

Corrosion performance of each resin system against aggressive media.

📚

Load & Span Tables

Read article →

Certified load classes and maximum clear spans by configuration.

📚

Grating Design Guide

Read article →

Support, bearing and expansion-gap design basics.

Need a Pump Stand?